Powerclad Scaffold Sheeting

Powerclad Scaffold Sheeting

  • Polyethylene reinforced with high tensile scrim
  • Suitable for both tube & fitting and modular scaffold systems
  • Choice of grades, with options conforming to BS 7955
  • Flame retardant options, LPCB approved to LPS125 and LPS1207
  FR Premium FR Standard Standard Lite
Weight 240gsm 170gsm 180gsm 170gsm
Flame Retardant LPS 1215
LPS 1207
BS 5867 Part 2B
BS 476 Part 12C
DIN 4102 B1
LPS 1215
LPS 1207
BS 5867 Part 2B
BS 476 Part 12C
N/A N/A
Tensile strength MD 800N/50mm
XD 750N/50mm
MD >630N/50mm
XD >630N/50mm
MD >630N/50mm
XD >630N/50mm
MD 500N/50mm
XD 500N/50mm
Colour Ivory Ivory Clear Clear
Standard Sizes

2.0 x 45m
2.2 x 40m
2.7 x 20m
3.0 x 45m
3.2 x 20m
4.0 x 45m

2.0 x 45m
2.2 x 40m
3.0 x 45m
4.0 x 45m 2.0 x 45m
2.2 x 40m
3.0 x 45m

 


 

LPCB-ISOQARPowerclad Scaffold Sheeting is a reinforced polyolefin sheeting system for temporary containment and weather protection applications. Powerclad reinforcement bands incorporate eyelets every 10cm to provide a versatile system for all tube & fitting and modular scaffolding systems and the ability to vary the support density according to anticipated wind forces.

Both flame retardant and non-flame retardant grades are available. Flame retardant grades are LPCB approved to LPS 1215 and LPS 1207. All grades (except Powerclad Lite) conform to BS 7955.

Industrial Textiles & Plastics Ltd is ISOQAR Quality Assured and certified to ISO 9001.

ITP's Scaffolding Team provides customer-specific service and technical support. Contact them on +44(0)1347 825200 or email powerclad@itpltd.com.

See Tech Base for more information about Certification and Compliance.


 

Installation

Powerclad Scaffold Sheeting is suitable for all tube & fitting and modular scaffolding systems. Install to BS 8410 Code of practice for lightweight temporary cladding for weather protection and containment on construction works.

We recommend using one bag (100) of Powerclad Powerties elasticated toggle per roll of scaffold sheeting for correct installation.

Certification and Compliance

BS 7955:1999 This British Standard is for: Containment nets and sheets for construction works. Specification for performance and test methods. It specifies the minimum tensile strength of the scaffold sheeting, the eyelet strength and the ties.

Flame Retardancy

LPCB The Loss Prevention Certification Board (LPCB) has been working with industry and government for more than 100 years to set the standards needed to ensure that fire and security products and services perform effectively. LPCB has confirmed third-party approval for Powerclad FR products as they meet LPS 1207 and 1215 flame retardant standards.

LPS 1207 Loss Prevention Standard (LPS) 1207: Requirements for the LPCB approval for fire performance of temporary protective covering materials for use in the interior of buildings. This standard describes the fire test methods and performance requirements for ignitability, flammability, smoke emission, toxic gas emission and oxygen index. The performance requirements are intended to ensure that protective coverings for floors, walls, furnishings or other fixtures and fittings, in sheet or preformed form, used internally during construction or refurbishment of buildings do not significantly add to the fire risk. In case of printed sheeting, ink can effect the flame retardancy of the materials and separate flame retardant tests are required to obtain LPCB accreditation.

LPS 1215 Loss Prevention Standard (LPS) 1215: Requirements for the LPCB approval and listing for Fire Performance of Containment Nets and Sheet Materials for External Use on Construction Sites. This standard describes methods of tests and performance requirements with regard to flammability. The requirements set are those which should ensure that scaffold cladding materials such as sheeting and netting used externally during construction, refurbishment or demolition of buildings should not add to the fire risk. In case of printed sheeting and similar to LPS 1207, ink can effect the flame retardancy of the materials and separate flame retardant tests are required to obtain LPCB accreditation.

BS 5867 PART 2B Specification for fabrics for curtains and drapes. Flammability requirements.

BS 476 PART 12C Ignitability by direct flame.

DIN 4102 B1 Fire behaviour of building materials and elements - Classification of building materials - Requirements and testing.

 


 

 
 